Temperature sensor in the remote control Clivet
IZ2-XY 27M-70M
- Full range: Single Split 9.000 ÷ 24.000 Btu/h, Multi Split 9.000 ÷ 24.000 Btu/h;
- Compatible with Single & Multi Split systems;
- Optional: Wi-Fi for the remote management with NetHome Plus application for Android and iOS;
- Multi-directional airflow: The air conditioning unit can distribute the flow of air in multiple directions: to better direct the flow within the room, it electronically adjusts the direction of the louvers both horizontally and vertically:
- The standard control can be used to easily set the desired louver position;
- Follow-me function: The system gives priority to the temperature sensor in the remote control and adjusts itself accordingly;
- Control by smartphone: Thanks to an optional accessory, it is possible to set the temperature, on/off and timer of the unit from the smartphone.
Sizes for NATIV - Single/Multi Split with Hiwall indoor unit
Specifications:
|
NATIV 27M, [9000 BTU] |
|
27M |
|
|
|
|
|
COOLING CAPACITY |
kW |
2,64 |
|
HEATING CAPACITY |
kW |
2,93 |
|
POWER SUPPLY - COOLING/HEATING |
kW |
0,73/0,73 |
|
ENERGY CLASS - COOLING/HEATING |
- |
A++/A+++ |
|
SEER - SEASONAL ENERGY EFFICIENCY RATIO |
- |
6,30 |
|
SCOP - SEASONAL COEFFICIENT OF PERFORMANCE |
- |
5,10 |
|
AIR FLOW (HI/MID/LO) |
m³/h |
466/360/325 |
|
SETTABLE TEMPERATURE |
°C |
17 ÷ 30 |
|
SOUND PRESSURE (OUTDOOR UNIT) |
dB(A) |
56 |
|
SOUND PRESSURE (INDOOR UNIT) |
dB(A) |
25 ÷ 39 |
|
POWER SUPPLY OUTDOOR UNIT (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
230/50/1 |
|
REFRIGERANT |
- |
R32 |
|
REFRIGERANT QUANTITY |
kg |
0,55 |
|
DIMENSIONS INDOOR UNIT (LENGHT/DEPTH/HEIGHT) |
mm |
805/194/285 |
|
DIMENSIONS OUTDOOR UNIT (LENGHT/DEPTH/HEIGHT) |
mm |
720/270/495 |
|
WEIGHT INDOOR UNIT |
kg |
7,6 |
|
WEIGHT OUTDOOR UNIT |
kg |
23,2 |
|
OPERATING RANGE - COOLING |
°C |
-15 ÷ 50 |
|
OPERATING RANGE - HEATING |
°C |
-15 ÷ 30 |
|
DIAMETER REFRIGERANT LIQUID PIPE/GAS PIPE |
mm |
6,35/9,52 |
Specifications:
|
NATIV 35M, [12000 BTU] |
|
35M |
|
|
|
|
|
COOLING CAPACITY |
kW |
3,52 |
|
HEATING CAPACITY |
kW |
3,81 |
|
POWER SUPPLY - COOLING/HEATING |
kW |
1,21/1,08 |
|
ENERGY CLASS - COOLING/HEATING |
- |
A++/A+++ |
|
SEER - SEASONAL ENERGY EFFICIENCY RATIO |
- |
6,10 |
|
SCOP - SEASONAL COEFFICIENT OF PERFORMANCE |
- |
5,10 |
|
AIR FLOW (HI/MID/LO) |
m³/h |
540/430/314 |
|
SETTABLE TEMPERATURE |
°C |
17 ÷ 30 |
|
SOUND PRESSURE (OUTDOOR UNIT) |
dB(A) |
56 |
|
SOUND PRESSURE (INDOOR UNIT) |
dB(A) |
25 ÷ 41 |
|
POWER SUPPLY OUTDOOR UNIT (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
230/50/1 |
|
REFRIGERANT |
- |
R32 |
|
REFRIGERANT QUANTITY |
kg |
0,55 |
|
DIMENSIONS INDOOR UNIT (LENGHT/DEPTH/HEIGHT) |
mm |
805/194/285 |
|
DIMENSIONS OUTDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
720/270/495 |
|
WEIGHT INDOOR UNIT |
kg |
7,6 |
|
WEIGHT OUTDOOR UNIT |
kg |
23,2 |
|
OPERATING RANGE - COOLING |
°C |
-15 ÷ 50 |
|
OPERATING RANGE - HEATING |
°C |
-15 ÷ 30 |
|
DIAMETER REFRIGERANT LIQUID PIPE/GAS PIPE |
mm |
6,35/9,52 |
Specifications:
|
NATIV 53M, [18000 BTU] |
|
53M |
|
|
|
|
|
COOLING CAPACITY |
kW |
5,27 |
|
HEATING CAPACITY |
kW |
5,57 |
|
POWER SUPPLY - COOLING/HEATING |
kW |
1,55/1,57 |
|
ENERGY CLASS - COOLING/HEATING |
- |
A++/A+++ |
|
SEER - SEASONAL ENERGY EFFICIENCY RATIO |
- |
7,40 |
|
SCOP - SEASONAL COEFFICIENT OF PERFORMANCE |
- |
5,10 |
|
AIR FLOW (HI/MID/LO) |
m³/h |
840/680/540 |
|
SETTABLE TEMPERATURE |
°C |
17 ÷ 30 |
|
SOUND PRESSURE (OUTDOOR UNIT) |
dB(A) |
56 |
|
SOUND PRESSURE (INDOOR UNIT) |
dB(A) |
26 ÷ 43 |
|
POWER SUPPLY OUTDOOR UNIT (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
230/50/1 |
|
REFRIGERANT |
- |
R32 |
|
REFRIGERANT QUANTITY |
kg |
1,08 |
|
DIMENSIONS INDOOR UNIT (LENGHT/DEPTH/HEIGHT) |
mm |
957/213/302 |
|
DIMENSIONS OUTDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
805/330/554 |
|
WEIGHT INDOOR UNIT |
kg |
10 |
|
WEIGHT OUTDOOR UNIT |
kg |
32,7 |
|
OPERATING RANGE - COOLING |
°C |
-15 ÷ 50 |
|
OPERATING RANGE - HEATING |
°C |
-15 ÷ 30 |
|
DIAMETER REFRIGERANT LIQUID PIPE/GAS PIPE |
mm |
6,35/12,70 |
Specifications:
|
NATIV 70M, [24000 BTU] |
|
70M |
|
|
|
|
|
COOLING CAPACITY |
kW |
7,03 |
|
HEATING CAPACITY |
kW |
7,33 |
|
POWER SUPPLY - COOLING/HEATING |
kW |
2,60/2,40 |
|
ENERGY CLASS - COOLING/HEATING |
- |
A++/A++ |
|
SEER - SEASONAL ENERGY EFFICIENCY RATIO |
- |
6,10 |
|
SCOP - SEASONAL COEFFICIENT OF PERFORMANCE |
- |
4,80 |
|
AIR FLOW (HI/MID/LO) |
m³/h |
980/817/662 |
|
SETTABLE TEMPERATURE |
°C |
17 ÷ 30 |
|
SOUND PRESSURE (OUTDOOR UNIT) |
dB(A) |
59 |
|
SOUND PRESSURE (INDOOR UNIT) |
dB(A) |
36 ÷ 45 |
|
POWER SUPPLY OUTDOOR UNIT (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
230/50/1 |
|
REFRIGERANT |
- |
R32 |
|
REFRIGERANT QUANTITY |
kg |
1,42 |
|
DIMENSIONS INDOOR UNIT (LENGHT/DEPTH/HEIGHT) |
mm |
1040/220/327 |
|
DIMENSIONS OUTDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
890/342/673 |
|
WEIGHT INDOOR UNIT |
kg |
12,3 |
|
WEIGHT OUTDOOR UNIT |
kg |
42,9 |
|
OPERATING RANGE - COOLING |
°C |
-15 ÷ 50 |
|
OPERATING RANGE - HEATING |
°C |
-15 ÷ 30 |
|
DIAMETER REFRIGERANT LIQUID PIPE/GAS PIPE |
mm |
9,52/15,90 |




