Energy class A+++ and superb design Sinclair
The air conditioners of the MARVIN series offer the highest level of equipment and a memorable design, emphasizing clean geometric shapes. This wall-mounted series is distinguished by high energy efficiency and class A+++, as well as the extremely useful humidity control function.
This is possible through an integrated relative humidity sensor, which allows drying the room to a precisely set value. In heating mode, it is possible to set a constant target temperature in the range of 8 to 30 degrees Celsius.
The Marvin series has a unique function for humidifying the outdoor unit, thus ensuring safe noise levels at night.
The standard equipment includes, in addition to the usual functions - Wi-Fi connection, movement of the slats in all directions, a plasma generator, a contact for blocking operation, the ability to connect a wall controller and others, also a UV-C lamp for even higher air quality.
Customers combining air conditioning with photovoltaic systems will certainly appreciate the possibility of limiting the maximum input power of the entire system to 50% or 75%. MARVIN indoor units are available in four colors - white, black, silver, champagne and navy blue. By adding the SWC-02 or SWC-04 wall controller, MARVIN units can be implemented in higher-level systems using Modbus or BACnet protocols.
Sizes for MARVIN - Series of colorful wall-mounted air conditioners
Specifications:
|
COOLING CAPACITY |
kW |
2,70 |
|
HEATING CAPACITY |
kW |
3,00 |
|
POWER INPUT - COOLING/HEATING |
kW |
0,67/0,68 |
|
RECOMMENDED COOLING VOLUME |
m³ |
40 |
|
RECOMMENDED HEATING VOLUME |
m³ |
35 |
|
ENERGY CLASS - COOLING/HEATING |
- |
A+++/A++ |
|
SEER - SEASONAL ENERGY EFFICIENCY RATIO |
W |
8,50 |
|
SCOP - SEASONAL COEFFICIENT OF PERFORMANCE |
W |
4,60 |
|
SOUND PRESSURE (OUTDOOR UNIT) |
dB(A) |
50 |
|
SOUND PRESSURE (INDOOR UNIT) |
dB(A) |
19 ÷ 38 |
|
POWER SUPPLY OUTDOOR UNIT (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
240/50/1 |
|
REFRIGERANT |
- |
R32 |
|
REFRIGERANT QUANTITY |
kg |
0,53 |
|
DIMENSIONS INDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
837/293/200 |
|
DIMENSIONS OUTDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
732/555/330 |
|
WEIGHT INDOOR UNIT |
kg |
9,5 |
|
WEIGHT OUTDOOR UNIT |
kg |
25 |
|
OPERATING RANGE - COOLING |
°C |
-15 ÷ 50 |
|
OPERATING RANGE - HEATING |
°C |
-25 ÷ 30 |
|
DIAMETER REFRIGERANT LIQUID PIPE/GAS PIPE |
mm |
6,0/9,5 |
Specifications:
|
COOLING CAPACITY |
kW |
3,50 |
|
HEATING CAPACITY |
kW |
3,80 |
|
POWER INPUT - COOLING/HEATING |
kW |
0,99/0,98 |
|
RECOMMENDED COOLING VOLUME |
m³ |
65 |
|
RECOMMENDED HEATING VOLUME |
m³ |
60 |
|
ENERGY CLASS - COOLING/HEATING |
- |
A++/A+ |
|
SEER - SEASONAL ENERGY EFFICIENCY RATIO |
W |
7,20 |
|
SCOP - SEASONAL COEFFICIENT OF PERFORMANCE |
W |
4,10 |
|
SOUND PRESSURE (OUTDOOR UNIT) |
dB(A) |
52 |
|
SOUND PRESSURE (INDOOR UNIT) |
dB(A) |
19 ÷ 41 |
|
POWER SUPPLY OUTDOOR UNIT (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
240/50/1 |
|
REFRIGERANT |
- |
R32 |
|
REFRIGERANT QUANTITY |
kg |
0,57 |
|
DIMENSIONS INDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
837/29,/200 |
|
DIMENSIONS OUTDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
732/555/330 |
|
WEIGHT INDOOR UNIT |
kg |
9,5 |
|
WEIGHT OUTDOOR UNIT |
kg |
25,5 |
|
OPERATING RANGE - COOLING |
°C |
-15 ÷ 50 |
|
OPERATING RANGE - HEATING |
°C |
-25 ÷ 30 |
|
DIAMETER REFRIGERANT LIQUID PIPE/GAS PIPE |
mm |
6,0/9,5 |
Specifications:
|
COOLING CAPACITY |
kW |
5,30 |
|
HEATING CAPACITY |
kW |
5,40 |
|
POWER INPUT - COOLING/HEATING |
kW |
1,53/1,39 |
|
RECOMMENDED COOLING VOLUME |
m³ |
115 |
|
RECOMMENDED HEATING VOLUME |
m³ |
95 |
|
ENERGY CLASS - COOLING/HEATING |
- |
A++/A+ |
|
SEER - SEASONAL ENERGY EFFICIENCY RATIO |
W |
7,30 |
|
SCOP - SEASONAL COEFFICIENT OF PERFORMANCE |
W |
4,20 |
|
SOUND PRESSURE (OUTDOOR UNIT) |
dB(A) |
56 |
|
SOUND PRESSURE (INDOOR UNIT) |
dB(A) |
23 ÷ 45 |
|
POWER SUPPLY OUTDOOR UNIT (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
240/50/1 |
|
REFRIGERANT |
- |
R32 |
|
REFRIGERANT QUANTITY |
kg |
0,85 |
|
DIMENSIONS INDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
993/311/222 |
|
DIMENSIONS OUTDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
802/555/302 |
|
WEIGHT INDOOR UNIT |
kg |
12,5 |
|
WEIGHT OUTDOOR UNIT |
kg |
31,5 |
|
OPERATING RANGE - COOLING |
°C |
-15 ÷ 50 |
|
OPERATING RANGE - HEATING |
°C |
-25 ÷ 30 |
|
DIAMETER REFRIGERANT LIQUID PIPE/GAS PIPE |
mm |
6,0/12,0 |
Specifications:
|
COOLING CAPACITY |
kW |
7,10 |
|
HEATING CAPACITY |
kW |
7,30 |
|
POWER INPUT - COOLING/HEATING |
kW |
2,03/1,87 |
|
RECOMMENDED COOLING VOLUME |
m³ |
135 |
|
RECOMMENDED HEATING VOLUME |
m³ |
125 |
|
ENERGY CLASS - COOLING/HEATING |
- |
A++/A+ |
|
SEER - SEASONAL ENERGY EFFICIENCY RATIO |
W |
7,00 |
|
SCOP - SEASONAL COEFFICIENT OF PERFORMANCE |
W |
4,30 |
|
SOUND PRESSURE (OUTDOOR UNIT) |
dB(A) |
59 |
|
SOUND PRESSURE (INDOOR UNIT) |
dB(A) |
27 ÷ 48 |
|
POWER SUPPLY OUTDOOR UNIT (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
240/50/1 |
|
REFRIGERANT |
- |
R32 |
|
REFRIGERANT QUANTITY |
kg |
1,40 |
|
DIMENSIONS INDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
993/311/222 |
|
DIMENSIONS OUTDOOR UNIT (WIDTH/HEIGHT/DEPTH) |
mm |
958/660/402 |
|
WEIGHT INDOOR UNIT |
kg |
17,5 |
|
WEIGHT OUTDOOR UNIT |
kg |
53,5 |
|
OPERATING RANGE - COOLING |
°C |
-15 ÷ 43 |
|
OPERATING RANGE - HEATING |
°C |
-22 ÷ 24 |
|
DIAMETER REFRIGERANT LIQUID PIPE/GAS PIPE |
mm |
6,0/16,0 |