The most efficient on the market Italtherm
Modulation ratio > 1:20
City Top is the only wall hung gas boiler in the world with a modulation range higher than 1:20.
This allows:
- a decrease in switching on and off
- silent operation
- reduced gas consumption and polluting emissions
- a longer life of the appliance
City Top is the most efficient and flexible boiler on the market, able to adapt to the actual heat requirement of the system.
It checks, adjusts, fits
Italtherm has developed the ICS (Intelligent Combustion System). Thanks to this system, City Top can be considered an intelligent boiler, checking, regulating and adapting itself independently.
The ICS controls combustion values and regulates gas flow in order to get always the correct air/gas ratio, thus obtaining:
- a reduction of gas consumption
- lower CO/CO2 emissions
- a shorter installation time (there are no manual adjustments to be made).
Silent and safe
City Top ensures the highest safety standards in the market thanks to the double sealing of the combustion group.
The double sealed chamber, further increasing the level of safety, improves the acoustic performance of City Top inside the home. City Top has thus reached the lowest noise levels in the market, to the benefit of comfort.
Design by Giugiaro
Creator of many of the most beautiful cars of the last 40 years for Lamborghini, Maserati, Bugatti, Volkswagen, Alfa Romeo and others, Eng. Giorgetto Giugiaro is also the most awarded car designer in the world ("Gold Compass" and "Car Designer of the Century").
With more than 1000 employees in his company (Italdesign), he has designed many products that made history in the industrial design too, e.g. Nikon F5, Minuetto Trenitalia, Airbus A321, Bimota, etc...)
Among his latest creations the aesthetics of the new line of Italtherm City series.
Sizes for City Top - Condensing gas boiler with modulation ratio 1:20
Specifications:
|
GAS TYPE |
- |
G20 |
|
MODULATION RATIO |
- |
1:16 |
|
NOMINAL HEAT INPUT IN DHW Qnw |
kW |
25,0 |
|
NOMINAL HEAT INPUT IN CH Qn |
kW |
25,0 |
|
MINIMUM HEAT INPUT Qmin |
kW |
1,6 |
|
USEFUL EFFICIENCY AT 30% OF THE HEAT INPUT η30 at Qn |
% |
107,0 |
|
HEATING ENERGY CLASS |
- |
А |
|
DHW ENERGY CLASS |
- |
А/XL |
|
FLOW RATE (ΔT 25°C) |
l/min |
15,0 |
|
DHW RANGE TEMPERATURE (MIN÷MAX) |
°C |
30÷55 |
|
NOMINAL VOLTAGE (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
230/50/1 |
|
POWER CONSUMPTION |
W |
87 |
|
ELECTRICAL PROTECTION LEVEL |
- |
IP X5D |
|
EXPANSION VESSEL |
l |
10 |
|
DIMENSIONS (WIDTH/HEIGHT/DEPTH) |
mm |
400/700/324 |
|
WEIGHT |
kg |
36,8 |
Specifications:
|
GAS TYPE |
- |
G20 |
|
MODULATION RATIO |
- |
1:20 |
|
NOMINAL HEAT INPUT IN DHW Qnw |
kW |
34,9 |
|
NOMINAL HEAT INPUT IN CH Qn |
kW |
33,0 |
|
MINIMUM HEAT INPUT Qmin |
kW |
1,6 |
|
USEFUL EFFICIENCY AT 30% OF THE HEAT INPUT η30 at Qn |
% |
108,0 |
|
HEATING ENERGY CLASS |
- |
А |
|
DHW ENERGY CLASS |
- |
А/XL |
|
FLOW RATE (ΔT 25°C) |
l/min |
20,0 |
|
DHW RANGE TEMPERATURE (MIN÷MAX) |
°C |
30÷55 |
|
NOMINAL VOLTAGE (VOLTAGE/FREQUENCY/PHASES) |
V/Hz/n* |
230/50/1 |
|
POWER CONSUMPTION |
W |
110 |
|
ELECTRICAL PROTECTION LEVEL |
- |
IP X5D |
|
EXPANSION VESSEL |
l |
10 |
|
DIMENSIONS (WIDTH/HEIGHT/DEPTH) |
mm |
400/700/324 |
|
WEIGHT |
kg |
36,8 |