Warning: unlink(/tmp/latte/dev.adnet.bg/app-layouts-dev.adnet.bg.php--ca90a10ad7.php.lock): No such file or directory in /var/www/dev.adnet.bg/public/index.php on line 70

Warning: unlink(/tmp/latte/dev.adnet.bg/index-views-products.php--d31bc84e8e.php): No such file or directory in /var/www/dev.adnet.bg/public/index.php on line 70
Edge F - Monoblock heat pump with R290 refrigerant | Biodom: Design of comfort

Clivet Edge F - Monoblock heat pump with R290 refrigerant

Air-to-water heat pump with capacity from 4 to 16 kW Clivet


The Edge F heat pump with propane refrigerant is designed for the future. Propane is a natural gas, and already compliant with the current strict European regulations. Propane for a sustainable future!
Edge F is the perfect solution for renovated properties, and indeed for all forms of heating, cooling and domestic hot water systems.

  • Wide operating range: The system is available in 7 sizes from 4 to 16 kW. Edge F can achieve a supply temperature of 75 °C when the ambient temperature is even as low as -10 °C, making it a superb alternative to a traditional boiler;
  • New way of use: new control system with coloured graphic interface, designed for maximum ease of use with the special Clivet design;
  • Adaptable: with many optional accessories, including an integrated pump and expansion tank, the various elements can be readily combined to suit any layout;
  • Very quiet: minimum noise levels, with 2 operating modes specially designed to ensure acoustic comfort;
  • Top performance: improved levels of performance, with class A++ at Medium Temperature (55 °C water supply), and class A+++ in Low Temperature heating (35 °C water supply). Edge F is also very efficient at cooling with SEER values of up to 5.86.

Sizes for Edge F - Monoblock heat pump with R290 refrigerant

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

4,50 / 6,86

COP - COEFFICIENT OF PERFORMANCE

-

5,15

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

4,70 / 5,66

EER - ENERGY EFFICIENCY RATIO

-

3,65

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

5,09

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

40 / 44

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

230/50/1

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

0,70

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1295/718/381

WEIGHT

kg

90

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 46

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

6,20 / 7,70

COP - COEFFICIENT OF PERFORMANCE

-

4,90

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

6,80 / 7,14

EER - ENERGY EFFICIENCY RATIO

-

3,10

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

4,91

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

42 / 46

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

230/50/1

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

0,70

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1295/718/381

WEIGHT

kg

90

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 46

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

8,40 / 10,40

COP - COEFFICIENT OF PERFORMANCE

-

5,00

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

7,50 / 8,19

EER - ENERGY EFFICIENCY RATIO

-

3,45

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

5,2

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

42 / 48

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

230/50/1

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

1,10

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1385/865/423

WEIGHT

kg

117

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 46

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

10,00 / 11,00

COP - COEFFICIENT OF PERFORMANCE

-

4,70

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

8,90 / 8,90

EER - ENERGY EFFICIENCY RATIO

-

3,25

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

5,07

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

43 / 49

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

230/50/1

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

1,10

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1385/865/423

WEIGHT

kg

117

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 46

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

12,00 / 14,70

COP - COEFFICIENT OF PERFORMANCE

-

4,80

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

11,50 / 12,00

EER - ENERGY EFFICIENCY RATIO

-

3,05

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

4,68

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

43 / 51

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

230/50/1

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

1,25

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1385/865/423

WEIGHT

kg

135

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 46

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

12,0 / 14,7

COP - COEFFICIENT OF PERFORMANCE

-

4,80

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

11,5 / 12,0

EER - ENERGY EFFICIENCY RATIO

-

3,05

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

4,68

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

43 / 51

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

400/50/3+N

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

1,25

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1385/865/423

WEIGHT

kg

137

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 43

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

14,00 / 16,00

COP - COEFFICIENT OF PERFORMANCE

-

4,50

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

12,70 / 12,70

EER - ENERGY EFFICIENCY RATIO

-

2,90

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

4,64

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

44 / 52

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

230/50/1

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

1,25

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1385/865/423

WEIGHT

kg

135

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 46

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

14,0 / 16,0

COP - COEFFICIENT OF PERFORMANCE

-

4,50

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

12,7 / 12,7

EER - ENERGY EFFICIENCY RATIO

-

2,90

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

4,64

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

44 / 52

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

400/50/3+N

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

1,25

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1385/865/423

WEIGHT

kg

137

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 43

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

15,00 / 17,60

COP - COEFFICIENT OF PERFORMANCE

-

4,40

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

14,00 / 14,30

EER - ENERGY EFFICIENCY RATIO

-

2,75

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

4,59

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

48 / 56

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

230/50/1

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

1,25

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1385/865/423

WEIGHT

kg

135

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 46

Specifications:

NOMINAL / MAXIMUM HEATING CAPACITY А7°/W35°

kW

15,0 / 17,6

COP - COEFFICIENT OF PERFORMANCE

-

4,40

NOMINAL / MAXIMUM COOLING CAPACITY A35°/W7°

kW

14,0 / 14,3

EER - ENERGY EFFICIENCY RATIO

-

2,75

ENERGY CLASS (HEATING WATER 35 °C)

-

A+++

SCOP - SEASONAL COEFFICIENT OF PERFORMANCE

-

4,59

MINIMUM / NOMINAL SOUND PRESSURE

dB(A)

48 / 56

POWER SUPPLY (VOLTAGE/FREQUENCY/PHASES)

V/Hz/n*

400/50/3+N

REFRIGERANT

-

R290

REFRIGERANT QUANTITY

kg

1,25

DIMENSIONS (WIDTH/HEIGHT/DEPTH)

mm

1385/865/423

WEIGHT

kg

137

OPERATING RANGE - HEATING

°C

-25 ÷ 35

OPERATING RANGE - COOLING

°C

-5 ÷ 43

Edge F - Monoblock heat pump with R290 refrigerant energy saving

Accessories

Edge F - Monoblock heat pump with R290 refrigerant information

Files for Edge F - Monoblock heat pump with R290 refrigerant

Keyboard - Manual.pdf (requires registration)
Product Sheet_EN.pdf (requires registration)

Latest News

Frequently Asked Questions

We will offer you options. They will be prepared by our engineers and designers based on the information you will submit to us.

Yes. An individual approach is among the company's values ​​and a guarantee that the customer will be satisfied.

Yes. We will offer you specific solutions according to the specific parameters and conditions.

Yes. We work flexibly and with a team capable of solving different cases

It depends on the type, parameters, condition of the building/apartment/office, on your wishes and possibilities.

Your monthly cost depends on many elements, including source of energy/heating/air conditioning, area, usage, system management. And also from the duration of the heating or warm season and its characteristics, for example temperature.

The factors are objective and subjective and are strictly individual for each project.

Yes, including a remote access application.

The solutions are individual, the main factor being the temperature requirements of the flooring manufacturer.
 

With us, you will find high-quality products for HVAC and air purification. Heat pumps, convectors, purifiers, air conditioning and ventilation equipment are in the portfolio of the company Biodom.

The selection of the equipment offered by us is made precisely and is based on both our great experience and high professionalism of the team, as well as established partners over the years.
We guarantee the quality of the products without a doubt, because in our practice we have worked with all of them. 

Biodom is the official distributor of Clivet for Bulgaria. Clivet is a company established and based in Italy, which in recent years has been expanding and enriching its product range with HVAC products.


Energy efficient

Of course, our desire to respond to customer wishes and global trends provokes us to seek, discover and offer technologies and machines that make the future seem closer. And in it, one of the main topics is energy efficiency. It will have more and more weight, especially after the European Union adopted the Directive on the energy performance of buildings. The document affects not only newly built residential and office units, but also older ones in which the air conditioning is solved with different types of technology.

Specific cases

At Biodom we have the capacity to find a solution for each individual case, because we know that the client relies on exactly this from the professionals - an expert opinion, an adequate proposal, good conditions and, of course, an excellent end result.
Whether it is an apartment, a single-family house, a larger residential building or a purpose-built office, we will provide you with options to ensure the comfort of living and staying.
A large part of the products we rely on to fulfill wishes are made in Europe, and our teams of specialists have visited our partners' factories.
Whether you are looking for an efficient heat pump, convector, air conditioner, fan, purifier, recuperator, kitchen ventilation, dehumidifier, air curtain, smart components and flexible solutions, or you need more power for heating, cooling, ventilation, air conditioning, we are there for you.

Because, for example, with us, the convectors come in variations - such as sizes, colors, installation method - ceiling mounted, built into the floor, such as power.
If you need a heat pump, with us you will receive professional advice on the most suitable option for you.
We can also offer floor and wall heating. For everything, we guarantee high quality and favorable prices.

preloader